Temperature Humidity Sensor Probe Sensitive Accurate Digital Soil Temp Humidity Sensor Probe DC3.3V

٧٤٫٠٠ د.إ.‏
+ ١٠٫٤٩ د.إ.‏ الشحن

Temperature Humidity Sensor Probe Sensitive Accurate Digital Soil Temp Humidity Sensor Probe DC3.3V

  • العلامة التجارية: Unbranded

Temperature Humidity Sensor Probe Sensitive Accurate Digital Soil Temp Humidity Sensor Probe DC3.3V

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٩٩٫٠٠ د.إ.‏
السعر: ٧٤٫٠٠ د.إ.‏
أنت توفر: ٢٥٫٠٠ د.إ.‏ (25%)
البائع:
٧٤٫٠٠ د.إ.‏
+ ١٠٫٤٩ د.إ.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Temperature Humidity Sensor Probe Sensitive Accurate Digital Soil Temp Humidity Sensor Probe DC3.3V Item Type: Temperature Sensor Probe Material: Copper, Plastic Mode: FS400 SHT45 Working Current: Less than 15mA Humidity Accuracy: ± 1.5% RH Temperature Accuracy: ± 0.1 ℃ Working Voltage: 3.3V Temperature Measurement Range: -20 ℃ to 100 ℃ Humidity Measurement Range: 0 to 100 percent RH Communication Interface: I ² C Working Conditions: -20 ℃ to 90 ℃, 0 to 99% RH Storage Conditions: -20 ℃ to 80 ℃, 0 to 95% RH Shell: Copper, Plastic Line Length: Approx. 150cm / 59.1in Product Features: 1. Digitization, with a resolution of up to 14 bits; 2. Internal self calibration, no calibration required; 3. The close combination of temperature and humidity is convenient for dew point measurement; 4. Anti rain, dust, rust, reliability and long term stability; Matters Needing Attention: The relative humidity of air is a function of temperature, and air temperature has a great impact on relative humidity. Various compounds such as acids, alkalis, and salts have a significant impact on the physical properties of water vapor. The following precautions should be taken when using: 1. The temperature and humidity sensor should be installed in a place where the temperature is relatively stable and can best represent the measured ambient temperature and humidity. 2. Avoid installing in places with drastic temperature changes. 3. Avoid installing in areas with intense air flow. 4. Avoid installing in dead corners where air does not flow. 5. Avoid using in salt spray environments. Avoid using in corrosive gas environments. Working Conditions: Long term exposure to conditions outside the normal range, especially when humidity exceeds 80%, may cause temporary signal drift (drift+3% RH after 60 hours). After returning to normal operating conditions, the sensor will slowly self recover to the calibration state. Prolonged use under abnormal conditions can accelerate the aging of the product.
  • هوية Fruugo: 432950356-908978926
  • EAN: 3061311113923

التسليم والرد

يُرسل خلال 24 ساعة

  • EXPRESS: ١٠٫٤٩ د.إ.‏ - التسليم في موعد أقصاه الخميس 20 نوفمبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة