LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry

٥٤٩٫٠٠ د.إ.‏
+ ٢٠٫٩٩ د.إ.‏ الشحن

LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry

  • العلامة التجارية: Unbranded

LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٨٧٤٫٠٠ د.إ.‏
السعر: ٥٤٩٫٠٠ د.إ.‏
أنت توفر: ٣٢٥٫٠٠ د.إ.‏ (37%)
البائع:
٥٤٩٫٠٠ د.إ.‏
+ ٢٠٫٩٩ د.إ.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry

LS195 Gloss Meter Intelligent Stone Metal Glossometer Gloss Testing Equipment for Industry Item Type: Gloss Meter Model: LS195 Material: ABS Battery: 1 x Rechargeable lithium battery 3.7V 650mAh (Battery Included) Purpose: Sampling and comparison of gloss measurement Application: Paint, coating, ink, plastic, paper, ceramic tile, ceramic, stone, metal, electroplating layer Measuring Angle: 60° Measuring Spot: Approx. 9 x 15 mm / 0.4 x 0.6 in Minimum Size of Test Object: Approx. 20 x 10 mm / 0.8 x 0.4 in Measuring Range: 0-200GU Resolution: 0.1GU Repeatability: 0-100GU: ±0.2GU 100-200GU: ±0.2% of reading Reproducibility: 0-100GU: ±0.5GU 100-200GU: ±0.5% of reading Zero Error: 0.1GU Indication Error: 0-100GU: ±1.5GU 100-200GU: ±1.5% of reading System Language: Chinese, English Display: 240 x 128 dot matrix LCD Charging Interface: USB (Type C) Data Interface: USB Operating Temperature Range: 10-45 ℃, 0-85%RH (non condensing) Storage Temperature Range: -10-60℃, 0-85%RH (no condensation) QC Judgment: √ Ambient Temperature Compensation: √ How e: 1. Power on/off Power on: In the off state, short press the instrument button to power on. Shut down: Long press the instrument button to shut down; the instrument will automatically shut down when there is no operation for more than 3 minutes machine. 2. Parameter setting In the shutdown state, long press the instrument button for 3S to enter the parameter setting mode: A. Language (Language) Short press the button to select Chinese or English, long press the button for 3S to complete the setting, and enter the following setting item. B. Mode selection Short press the button to select normal mode or QC mode, long press the button for 3S to complete the setting, exit the setting and enter the calibration interface. 3. Equipment calibration Put the instrument on the standard board and turn on the opportunity to enter the calibration interface. The user can perform the calibration operation according to the calibration prompt, and the measurement interface will be entered after the calibration is passed. If the instrument is turned on without putting it on the standard board, it will skip the calibration and enter the measurement interface directly. If it prompts that the calibration failed, the possible reasons are as follows: The standard board is dirty, please wipe the standard board clean with a special lens cloth, and then buckle the host into the base. The host is not close to the standard board, please buckle it into the base again. When the ambient temperature changes significantly, the instrument temperature and the ambient temperature should be close to each other, and after confirming that the lens in the test port of the instrument and the standard plate of the base are not dew, restart the measurement. The attenuation of the light source can not be used normally, and it needs to be returned to the factory for inspection and repair. When the instrument prompts "Calibration failed", you can long press the button to skip the calibration. 4. Measure (1) Normal mode If the instrument is set to normal mode, after the calibration of the instrument is completed, remove the base and place the measuring port of the instrument on the surfaces of the object to be measured, and the instrument will display the measured value at that place in real time. Short press the button, the lower left corner of the interface displays the "HOLD" sign, and the measurement data is held on the LCD. If you need to measure again, press the button to cancel the "HOLD" state and return to the "Measuring" state. (2) QC mode If the instrument is set to QC mode, after the instrument is calibrated, remove the base, place the measuring port of the instrument on the surfaces of the object to be measured, and short-press the button to perform the measurement. After the measurement, the measured value will be judged whether it is qualified. The range of the upper and lower limits must be set by PC software. For specific operations, please refer to the "Gloss Meter Software Operation Manual".
  • هوية Fruugo: 397056493-847241192
  • EAN: 6921316718264

التسليم والرد

يُرسل خلال 24 ساعة

  • STANDARD: ٢٠٫٩٩ د.إ.‏ - التسليم بين الخميس 11 ديسمبر 2025 – الجمعة 19 ديسمبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659