Linear Scale Encoder High Accuracy 5μm Grating Ruler Sensor for Lathe DC5V with Cable900

٢٬٣٩٩٫٠٠ د.إ.‏
+ ٥٣٫٤٩ د.إ.‏ الشحن

Linear Scale Encoder High Accuracy 5μm Grating Ruler Sensor for Lathe DC5V with Cable900

  • العلامة التجارية: Unbranded

Linear Scale Encoder High Accuracy 5μm Grating Ruler Sensor for Lathe DC5V with Cable900

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٣٬١٩٩٫٠٠ د.إ.‏
السعر: ٢٬٣٩٩٫٠٠ د.إ.‏
أنت توفر: ٨٠٠٫٠٠ د.إ.‏ (25%)
البائع:
٢٬٣٩٩٫٠٠ د.إ.‏
+ ٥٣٫٤٩ د.إ.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Linear Scale Encoder High Accuracy 5μm Grating Ruler Sensor for Lathe DC5V with Cable900 Item Type: Linear Scale Encoder Plug Type: DB9 Input Voltage: 5VDC Accuracy: 5μm Resolution: Approx. 0.005 mm/0.0002 inch Grating Pitch: 0.02mm Cable Length: Approx. 3 meters / 9.8ft Notes: 1. When plugging or unplugging the grating ruler sensor and the digital display plug socket, turn off the power. 2. Add a protective cover as much as possible, and clean up the chips and oil splashed on the ruler in time to strictly prevent any foreign matter from entering the inside of the grating ruler sensor housing. 3. Regularly check whether the installation connecting screws are loose. 4. In order to prolong the life of the dust-proof sealing strip, a thin layer of silicone oil can be evenly coated on the sealing strip, taking care not to splash it on the engraved surface of the glass grating. 5. In order to ensure the reliability of the grating scale sensor, the grating scale surface and the indicating grating surface can be cleaned and wiped with ethanol mixture (50% each) at regular intervals to keep the glass grating scale surface clean. 6. The grating ruler sensor is strictly prohibited from violent vibration and beating to avoid damage to the grating ruler. If the grating ruler breaks, the grating ruler sensor will fail. 7. Do not disassemble the grating scale sensor by yourself, let alone change the relative distance between the main scale and the auxiliary scale arbitrarily, otherwise the accuracy of the grating scale sensor may be damaged on the one hand; on the other hand, the main scale and the auxiliary scale may be damaged. Relative friction, damaging the chromium layer will also damage the grid lines, and cause the grating ruler to be scrapped. 8. Attention should be paid to prevent the grating ruler surface from being polluted by oil and water, so as not to damage the line stripe distribution of the grating ruler and cause measurement errors. 9. The grating sensor should try to avoid working in a severely corrosive environment, so as not to corrode the chromium layer of the grating and the surface of the grating and damage the quality of the grating. 
  • هوية Fruugo: 413777904-874400604
  • EAN: 4991337941776

التسليم والرد

يُرسل خلال 24 ساعة

  • EXPRESS: ٥٣٫٤٩ د.إ.‏ - التسليم في موعد أقصاه الجمعة 26 سبتمبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة