HP7200B TRMS Clamp Meter 6000 Counts 26mm NCV Voltage Resistance

١٩٩٫٠٠ د.إ.‏
+ ١٠٫٤٩ د.إ.‏ الشحن

HP7200B TRMS Clamp Meter 6000 Counts 26mm NCV Voltage Resistance

  • العلامة التجارية: Unbranded

HP7200B TRMS Clamp Meter 6000 Counts 26mm NCV Voltage Resistance

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٢٦٩٫٠٠ د.إ.‏
السعر: ١٩٩٫٠٠ د.إ.‏
أنت توفر: ٧٠٫٠٠ د.إ.‏ (26%)
البائع:
١٩٩٫٠٠ د.إ.‏
+ ١٠٫٤٩ د.إ.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

HP7200B TRMS Clamp Meter 6000 Counts 26mm NCV Voltage Resistance

HP7200B TRMS Clamp Meter 6000 Counts NCV Dc AC Voltage Resistance Temperature Multimeter Condition: Item Type: Clamp Meter Material: ABS General Characteristics Maximum Display 6000 Measuring Principle Double integral A/D conversion Sampling Rate 2~3 times per second Polarity Display Negative polarity input shows "-" Over-Range Display Display "OL" or "-OL" Low Battery Display Display symbols Auto Range Function   Automatic Shutdown Function About 15 minutes after power-on, the meter will automatically shut down, press any key or turn the function selection switch to turn it on again. Press and hold the "SEL" key to turn on the device to release the automatic shutdown function. Safety Standard The instrument has passed the IEC-1010 double insulation, environmental pollution degree 2 degree, overvoltage category CAT Ⅱ 600V or CAT Ⅲ 300V safety standard promulgated by the International Electrotechnical Commission. Working Environment Temperature 0-40℃, relative humidity≤80% Storage Environment Temperature -20-60℃, relative humidity ≤90% Power Supply 2 x AAA dry batteries (not included) Clamp Head Opening Size 26mm/1in Parameter DC Voltage (DCV) Range Resolution Accuracy 600mV 0.1mV ±(0.5% reading + 2 digits) 6V 1mV ±(0.5% reading + 2 digits) 600V 100mV ±(0.8% reading + 2 digits) Overload Protection 600V DC or AC RMS Input Resistance 10MΩ, 600mV range is greater than 100MΩ AC Voltage (ACV) (True RMS) Range Resolution Accuracy 6V 1mV ±(1.0% reading + 3 digits) 60V 10mV ±(1.0% reading + 3 digits) 600V 100mV ±(1.5% reading + 3 digits) Overload Protection 600V DC or AC RMS Input Resistance 10MΩ Measuring Frequency Range 40-2kHz DC Current (DCA) Range Resolution Accuracy 60A 10mA ±(2.5% reading + 10 digits) 400A 100mA ±(3.0% reading + 10 digits) Overload Protection 400A DC or AC RMS AC Current (ACA) (True RMS) Range Resolution Accuracy 60A 10mA ±(2.5% reading + 10 digits) 400A 100mA ±(3.0% reading + 10 digits) Overload Protection 400A DC or AC RMS Measuring Frequency Range 40-100Hz Resistance (Ω) Range Resolution Accuracy 600Ω 0.1Ω ±(1.0% reading + 3 digits) 6kΩ 1Ω ±(1.0% reading + 2 digits) 60kΩ 10Ω ±(1.0% reading + 2 digits) 600kΩ 100Ω ±(1.0% reading + 2 digits) 6MΩ 1kΩ ±(1.0% reading + 2 digits) 60MΩ 10kΩ ±(1.5% reading + 3 digits) Overload Protection 250V DC or AC RMS Capacitance (CAP) Range Resolution Accuracy 6nF 1pF ±(5.0% reading + 10 digits) 60nF 10pF ±(3.0% reading + 10 digits) 600nF 100pF ±(3.0% reading + 10 digits) 69μF 1nF ±(3.0% reading + 10 digits) 60μF 10nF ±(5.0% reading + 10 digits) 600μF 100nF ±(10.0% reading + 20 digits) 6mF 1μF ±(10.0% reading + 20 digits) 60mF 10μF ±(10.0% reading + 20 digits) Overload Protection 250V DC or AC RMS Frequency (Hz) Range Resolution Accuracy 9.999Hz 0.001Hz ±(0.1% reading + 5 digits) 99.99Hz 0.01Hz ±(0.1% reading + 5 digits) 999.9Hz 0.1Hz ±(0.1% reading + 5 digits) 9.999kHz 1Hz ±(0.1% reading + 5 digits) 99.99kHz 10Hz ±(0.1% reading + 5 digits) 999.9kHz 100Hz ±(0.1% reading + 5 digits) 9.999MHz 1kHz ±(0.1% reading + 5 digits) Test Sensitivity 0.6V AC RMS (9.999MHz file: 1.5V AC RMS) Overload Protection 250V DC or AC RMS Duty Cycle Measuring Range 0.1%~99.9% Accuracy ±(2.0% reading + 2 digits) The frequency is lower than 10kHz, higher than 10kHz can not guarantee accuracy Sensitivity 0.6V AC RMS Overload Protection 250V DC or AC RMS Temperature (℃/℉) Range Resolution Accuracy -20-150℃ 1℃ ±(3℃ + 1 digits) 150-1000℃ 1℃ ±(3% reading + 2 digits) -4-302℉ 1℉ ±(5℉ + 2 digits) 302-1832℉ 1℉ ±(3% reading + 3 digits) NiCr-NiSi K Type Thermocouple Overload Protection 250V DC or AC RMS Diode Detection Resolution 1mV Function Read the forward voltage across the diode at an instant Overload Protection 250V DC or AC RMS Instantaneous DC Current About 1.5mA Reversed DC Voltage About 4V On-Off Detection When the resistance of the component or loop under test is less than 50Ω, the buzzer will sound and the flashlight will light up at the same time Overload Protection 250V DC or AC RMS Open Circuit Voltage About 2V Non-Contact AC Voltage (NCV) Detection Detection Voltage Range 90V-1000V AC RMS When an AC voltage signal is sensed, the flashlight will light up and the buzzer will sound.
  • هوية Fruugo: 407590100-863778644
  • EAN: 4691329920474

التسليم والرد

يُرسل خلال 24 ساعة

  • STANDARD: ١٠٫٤٩ د.إ.‏ - التسليم بين الأربعاء 10 ديسمبر 2025 – الخميس 18 ديسمبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659