Features: _x000D_
This temperature controller is designed with dual-color LED display and has high precision of 0.1. _x000D_
_x000D_
It supports temperature correction, temperature alarm and delayed start function._x000D_
_x000D_
Designed with screw terminals for convenient and easy wiring._x000D_
_x000D_
Water-resistant probe has higher sensitivity, sealed with silicone, more suitable for liquid temperature detection, safe and durable._x000D_
_x000D_
Widely used for temperature control in cabinets, industrial equipment, vegetable and flower greenhouses, etc. _x000D_
_x000D_
_x000D_
Specifications: _x000D_
Control Range -50~110 _x000D_
Control Precision 0.1 _x000D_
Sensor Input NTC10K water-resistant sensor L=0. 5M _x000D_
Temperature Alarm -49~110 _x000D_
Input Voltage DC12V _x000D_
Output Type Relay output max. 10A _x000D_
Return Difference Set_x000D_
0.1~30 _x000D_
Delay Start 0~10minutes _x000D_
Temperature Correction -10~+10 _x000D_
Red Display_x000D_
Measured Temperature_x000D_
_x000D_
Green Display_x000D_
Setting Temperature_x000D_
_x000D_
_x000D_
_x000D_
_x000D_
Instruction: _x000D_
K0 K1 Terminal:_x000D_
Thermostat output type is relay output, K0 and K1 is equivalent to a extension relay switch; 12V power supply powers the thermostat, sensor detects temperature, internal temperature control program control relay output and load (if the load is powered by AC power supply, it is safer to connect K0 and K1 to live wire) _x000D_
Code Function Setting Range Default _x000D_
P0 Temperature Control Mode H(hot)/C(cold) C _x000D_
P1 Return Difference Setting 0.1~30 2 _x000D_
P2 Temperature Correction -10~10 0 _x000D_
P3 Delay Start 0~10 (min.) 0 _x000D_
P4 Temperature Alarm -49~110 110 _x000D_
_x000D_
"SET" Button: Set switch_x000D_
"+" Button: Increase temperature_x000D_
"-" Button: Reduce temperature_x000D_
Restore to Factory Settings: Power on, press and hold "+" and "-" buttons together for about 3 seconds. _x000D_
P0 Temperature Control Mode:_x000D_
This parameter must be set for first time using controller. If used for heating, set it as H; if used for cooling, set it as C._x000D_
P1 Return Difference:_x000D_
Press and hold SET button to enter internal setting, select P1 setting, press the SET button again to set return difference value. (Return difference value is the value that controller restarts after it reached set temperature and stopped. For example, if we use heating mode, make controller stops at 40 and restart at 35, the return difference value is 5)_x000D_
P2 Temperature Correction:_x000D_
This function is used for temperature correction, if there is a deviation between measured temperature and real temperature. Correcting Temperature= Measured Temperature + Correction Value. _x000D_
For example, if the measured temperature is 25.6 degrees and the actual temperature is 25.8 degrees, set P4 as 0.2, so the final temperature is 25.6 + 0.2 = 25.8 degrees_x000D_
P3 Delay Start:_x000D_
This function is normally used for compressor refrigeration. If controller is used in refrigerator freezers, this value must be set. According to back pressure of compressor, this value can be set between 3 and 6 minutes. If you don't use it to control compressor or don't need delay function, you can ignore it._x000D_
P4 Temperature Alarm:_x000D_
Set temperature alarm value, when the real-time temperature exceeds this value, the display will flash to alarm._x000D_
_x000D_
Heating mode setting example:_x000D_
Control electric heating equipment to stop heating at 35, and restart when temperature is down to 30;_x000D_
1, Press and hold SET button for 3 seconds to enter internal setting, set P0 as H._x000D_
2, Press and hold SET button to return to the real-time temperature display, press SET button again and the green display flashes, then adjust the value to 35._x000D_
3, The default return difference is 2, it need to be set as 5 if want to restart at 30. Press and hold SET button to enter internal setting, select P1, change P1 value to 5. _x000D_
_x000D_
_x000D_
Cooling mode setting example:_x000D_
Control air conditioning refrigeration to stop cooling at 23, and restart when the temperature is up to 27;_x000D_
1, Press and hold SET button for 3 seconds to enter internal setting, set P0 as C._x000D_
2, Press and hold SET button to return to the real-time temperature display, press SET button again and the green display flashes, then adjust the value to 23._x000D_
3, The default return difference is 2, it need to be set as 4 if want to restart at 27._x000D_
Press and hold SET button to enter internal setting, select P1, change P1 value to 4. _x000D_