Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

٥٤٫٠٠ د.إ.‏
+ ٣٦٫٤٩ د.إ.‏ الشحن

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

  • العلامة التجارية: Unbranded

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ١٠٤٫٠٠ د.إ.‏
السعر: ٥٤٫٠٠ د.إ.‏
أنت توفر: ٥٠٫٠٠ د.إ.‏ (48%)
البائع:
٥٤٫٠٠ د.إ.‏
+ ٣٦٫٤٩ د.إ.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Item Type:Relay Module Product Model: YF-11 Input Voltage:DC7~24V Output Power: Can Control DC Power Load within 10A Time Range: 0.01 Second to 999 Minutes, Any Time Adjustable Function: Pulse Trigger Cycle, Timing, Delay, Power Tube, mos Tube, Field Effect Tube, Switch, Relay Switch Application: It is Often Used to Control Motors, LED Light Strips, DC Motors, Micro Water Pumps, Solenoid Valves, Etc. P-21: Give the signal, after a delay of A second, the output starts P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops P-24: There is a signal. After A second, the output starts, and after the signal disappears for more than A second, the output stops. P-25: When there is a signal, the output will start after A second, and the output will stop when there is another signal for more than A second P-26: There is a signal, the output stops after A second, and the signal disappears and the output stops after A second. P-27: Detection of a pulse signal, the output stops; no pulse signal, more than A second output start; (the signal continues or the signal disappears are regarded as no pulse signal) P-28: After power on, after a delay of A second, the output starts until the power is off P-31: After power on, the output starts for A second, stops for B second, infinite loop; power off stops P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop P-34: After power-on, after a delay of A second, the output will start, and it will stop after closing B seconds P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull-in for B seconds P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped. P-37: When there is a signal, the output starts and stops automatically for A second, and then counts for B seconds after it stops. The signal trigger is invalid within A+B time P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops P-41: No action with signal; trigger when signal disappears; disconnect after output start delay A time P-42: The signal disappears, after a delay of time A, the output starts; working time B ends P-43: The signal disappears. After the time A exceeds, the output starts; the working time B ends P-44: After power on, the output will start A time, stop B time; cycle C times and automatically stop. P-45: No action when energized, after signal is given; output starts A time, stops B time; cycle C times and automatically stops; Give signal again, execute again P-46: After giving the signal more than A times, the output will start; keep the output; stop when the power is off P-47: After giving the signal more than A times, the output starts and stops for B seconds P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds 3. Description of button setting: Power on display "" means entering standby state; Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit) Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit) Press K1 for the fourth time, the display "" means entering the standby state Press K4 in standby mode to permanently turn off/on the display and switch to low power consumption mode 4. The decimal point time unit description: X.XX The decimal point is in hundreds, and the timing range: 0.01 seconds to 9.99 seconds XX.X The decimal point is in the tenth place, timing range: 0.1 second to 99.9 seconds XXX has no decimal point, timing range: 1 second to 999 seconds XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes
  • هوية Fruugo: 321526152-713414810
  • EAN: 1121763908682

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

تحذيرات السلامة: Do not let your children touch this product alone to avoid swallowing or other injuries.

التسليم والرد

يُرسل خلال ٣ أيام

  • STANDARD: ٣٦٫٤٩ د.إ.‏ - التسليم بين الجمعة 31 أكتوبر 2025 – الجمعة 07 نوفمبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15625700418

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611