Micrometer 0-25mm 0.01mm Outer Vernier Caliper for Precision Metal Measuring and Engineering

٦٤٫٠٠ د.إ.‏
والشحن مجاناً

Micrometer 0-25mm 0.01mm Outer Vernier Caliper for Precision Metal Measuring and Engineering

  • العلامة التجارية: Unbranded

Micrometer 0-25mm 0.01mm Outer Vernier Caliper for Precision Metal Measuring and Engineering

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٩٩٫٠٠ د.إ.‏
السعر: ٦٤٫٠٠ د.إ.‏
أنت توفر: ٣٥٫٠٠ د.إ.‏ (35%)
البائع:
٦٤٫٠٠ د.إ.‏
والشحن مجاناً

في المخزون

سياسة الإرجاع لمدة 14 يوما

نقبل وسائل الدفع الآتية

الوصف

Micrometer 0-25mm 0.01mm Outer Vernier Caliper for Precision Metal Measuring and Engineering

Product description and user instructions Key benefits Accurate, repeatable outside measurements for parts in the 0–25 mm range. Simple zero adjustment and mechanical locking for consistent results and easy calibration. Built-in ratchet/force control (clicks) helps ensure the same measuring force each time, reducing user error. What this product does Measures external dimensions (diameters, thicknesses, lengths) within the 0–25 mm range. Provides a calibrated baseline that can be corrected if the zero lines are not aligned. Includes a locking device to hold a measurement for recording or comparison. Important attributes Measuring range: 0–25 mm (for the direct-alignment model). Zeroing method: direct alignment using a 25 mm gauge (bar gauge) to establish quasi-zero. Adjustment method: mechanical sleeve/screw adjustment with screwdriver and wrench for fine zero correction. Measuring control: rotating thimble/ratchet that provides audible clicks to indicate consistent contact force. Locking: manual lock that secures the spindle position to retain measurements. Preparation and zero check Clean the measuring faces and anvil thoroughly before use to remove debris, oil, or burrs. For the 0–25 mm model, place a 25 mm gauge block (bar gauge) between the measuring faces to obtain the quasi-zero position before final zero adjustment. Zero correction procedure If the zero line on the thimble is not aligned with the baseline when closed on the gauge block: Slightly loosen the locking screw with a screwdriver. Use the supplied wrench to rotate the sleeve/spline to shift the baseline until the 0 line and the baseline align. Tighten the locking screw securely once alignment is correct. Refer to the product user manual illustrations for the exact screw and sleeve locations if needed. Measuring technique Hold the micrometer so it is perpendicular to the workpiece surface. Ensure stable contact between measuring faces and the part. Rotate the thimble using the ratchet/force control until the measuring faces make contact. The ratchet will produce slight "click, click..." sounds; the final click indicates the proper measuring force and the correct reading. Read the scale when the ratchet has engaged and the clicks indicate stable contact. Locking and measurement retention To lock a measurement, move the locking lever or knob to the left (lock position). To release and continue measuring, move the locking lever or knob to the right (release/relax position). Use the lock to hold readings for recording or to transfer the micrometer without losing the set position. Practical use scenarios Quality control inspection: Verify external diameters of shafts, pins, and small machined parts to ensure they meet tolerance. Workshop layout and setup: Measure thicknesses of shims, washers, and small components when fitting assemblies. Maintenance and repair: Check wear on rotating parts or measure replacement parts to confirm correct sizing. Care and best practices Always clean measuring faces before and after use. Avoid applying excessive force; allow the ratchet to set the measuring pressure. Store the micrometer in its protective case to prevent damage and contamination. Re-check zero periodically and after any shock or rough handling. Notes Follow the provided user manual diagrams for screw and sleeve positions during zero correction. Use only appropriate gauge blocks or bar gauges for calibration and zero setting.
  • هوية Fruugo: 404780229-858907434
  • EAN: 154321824132

التسليم والرد

يُرسل خلال 24 ساعة

  • STANDARD: مجاناً - التسليم بين الاثنين 29 ديسمبر 2025 – الأربعاء 14 يناير 2026 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • MystiqueMuse
  • Shenzhen Tuku Supply Chain Co., Ltd.
  • 202-5, Jinhe Building, 8 Xinhe Street
  • Maan Tang, Bantian , Longgang, Shenzhen, Guangdong
  • China
  • Guangdong
  • CN
  • 518129
  • caryleroot@outlook.com
  • 13428666765

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • Synertrade FR SAS
  • Synertrade FR SAS
  • 9 rue du Bat d'Argent
  • Lyon
  • France
  • Lyon
  • FR
  • 69001
  • info@syner-sarl.cn
  • (+33)774555006
  • https://seller.kuajingmaihuo.com/settle/qualification-service