Stepper Motor Driver Digital Display 42 57 Step Motor Drive Controller 5V?24V DM542L

٣٠٩٫٠٠ د.إ.‏
+ ٣٦٫٩٩ د.إ.‏ الشحن

Stepper Motor Driver Digital Display 42 57 Step Motor Drive Controller 5V?24V DM542L

  • العلامة التجارية: Unbranded

Stepper Motor Driver Digital Display 42 57 Step Motor Drive Controller 5V?24V DM542L

  • العلامة التجارية: Unbranded
السعر: ٣٠٩٫٠٠ د.إ.‏
البائع:
٣٠٩٫٠٠ د.إ.‏
+ ٣٦٫٩٩ د.إ.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Item Type: Stepper Motor Driver Parameter: DM542L Minimum Continuous Output Current: 1A Maximum Continuous Output Current: 4.2A Minimum Input Power Supply Voltage: 18V DC Typical Input Power Supply Voltage: 24V DC Maximum Input Power Supply Voltage: 48V DC Minimum Logic Input Current: 7mA Typical Logic Input Current: 10mA Maximum Logic Input Current: 20mA Maximum Power of The Whole Machine: 100W Pulse Frequency: 0-200kHz Minimum Insulation Resistance: 500M Maximum Logic Current of Digital Output Port: 100mA Maximum Withstand Voltage of Digital Output Port: 24V Cooling Mode: Natural cooling or external radiator. Usage: Avoid dust, oil mist and corrosive gas. Temperature: 0 - 50 Ambient Humidity: 40-90% RH Operating Environment Vibration: 10~55Hz/0.15mm Storage Temperature: -20- +65 Interface definition: Terminal 1 Symbol: A+ Terminal 1 Name: A Phase Motor Winding+ Terminal 1 Wire Color Terminal 2 Symbol: A- Terminal 2 Name: A Phase Motor Winding- Terminal 2 Wire Color Terminal 3 Symbol: B+ Terminal 3 Name: B Phase Motor Winding+ Terminal 3 Wire Color Terminal 4 Symbol: B- Terminal 4 Name: B Phase Motor Winding- Terminal 4 Wire Color Terminal 5 Symbol: VCC Terminal 5 Name: Input DC Voltage Positive Terminal 5 Wire Color 18-48V DC Terminal 6 Symbol: GND Terminal 6 Name: Input DC Voltage Negative Terminal 6 Wire Color 18-48V DC Control Signal Terminal: Terminal 1 Symbol: DIR- Terminal 1 Name: Direction Negative Input Terminal 1 Signal source +5V~24V universal, no need to connect resistance in series. Terminal 2 Symbol: DIR+ Terminal 2 Name: Direction Positive Input Terminal 2 Signal source +5V~24V universal, no need to connect resistance in series. Terminal 3 Symbol: PUL- Terminal 3 Name: Pulse Negative Input Terminal 3 Signal source +5V~24V universal, no need to connect resistance in series. Terminal 4 Symbol: PUL+ Terminal 4 Name: Pulse Positive Input Terminal 4 Signal source +5V~24V universal, no need to connect resistance in series. Terminal 5 Symbol: ENA- Terminal 5 Name: Motor Enable Negative Input Terminal 5 When the signal is valid, the motor is in free state and does not stall. Terminal 6 Symbol: ENA+ Terminal 6 Name: Motor Enable Positive Input Terminal 6 When the signal is valid, the motor is in free state and does not stall. Terminal 7 Symbol: ALM- Terminal 7 Name: Alarm Signal Negative Output Terminal 8 Symbol: ALM+ Terminal 8 Name: Alarm Signal Positive Output Fault Fault Coding 1: Er01 Fault Description 1: Motor Overcurrent Solution 1: Return to factory for inspection. Fault Coding 2: Er02 Fault Description 2: Drive Overvoltage Solution 2: Detect whether the motor is short-circuited or reduce the current. Fault Coding 3: Er03 Fault Description 3: Hardware Fault Solution 3: Check whether the input voltage is too high. Parameter Monitoring Function Coding 1: L-00 Function Description 1: Speed Function Introduction 1: Monitor the current speed, voltage and current in real time, check whether the driver works normally, and solve it in time in case of abnormality. Function Coding 2: L-01 Function Description 2: Pulse Speed Function Introduction 2: Monitor the current speed, voltage and current in real time, check whether the driver works normally, and solve it in time in case of abnormality. Function Coding 3: L-02 Function Description 3: Given Pulse Number Function Introduction 3: Monitor the current speed, voltage and current in real time, check whether the driver works normally, and solve it in time in case of abnormality. Function Coding 4: L-03 Function Description 4: Useless Function Introduction 4: Monitor the current speed, voltage and current in real time, check whether the driver works normally, and solve it in time in case of abnormality. Function Coding 5: L-05 Function Description 5: Driver Fault Coding Function Introduction 5: Check the number of received pulses in real time to determine whether the motor is out of step._x00
  • هوية Fruugo: 407735236-864092427
  • EAN: 4853222611396

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

تحذيرات السلامة: Do not let your children touch this product alone to avoid swallowing or other injuries

التسليم والرد

يُرسل خلال ٣ أيام

  • STANDARD: ٣٦٫٩٩ د.إ.‏ - التسليم بين الجمعة 17 أكتوبر 2025 – الثلاثاء 28 أكتوبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة